logo
Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
बोली
घर > उत्पादों >
केबल दोष खोजक
>
High Voltage Surge Generator with Built-in 2μF Capacitor and 1225J Discharge Power

High Voltage Surge Generator with Built-in 2μF Capacitor and 1225J Discharge Power

उत्पाद का विवरण:
उत्पत्ति के प्लेस: शीआन शानक्सी चीन
ब्रांड नाम: XZH TEST
प्रमाणन: ISO CE
मॉडल संख्या: XHHV535-2T
विस्तृत जानकारी
उत्पत्ति के प्लेस:
शीआन शानक्सी चीन
ब्रांड नाम:
XZH TEST
प्रमाणन:
ISO CE
मॉडल संख्या:
XHHV535-2T
प्रमुखता देना:

High Light

प्रमुखता देना:

Built-in capacitor 2μF High Voltage Surge Generator

,

Discharge power 1225J HV Surge Generator

,

High Voltage Surge Generator

Trading Information
न्यूनतम आदेश मात्रा:
1 सेट
पैकेजिंग विवरण:
लकड़ी की पैकेजिंग
प्रसव के समय:
5-8 कार्य दिवस
भुगतान शर्तें:
टी/टी
आपूर्ति की क्षमता:
3000यूनिट/वर्ष
उत्पाद का वर्णन

Description

When the XHHV535-2T trolley-type high-voltage surge generator is in use, after selecting the function switch, press the start button to perform high-voltage boosting work. After use, press the stop button, and the internal system will automatically release the remaining high voltage on the accumulator.

 

The device also has the function of zero-start protection, which can make the operation of the device more safe and reliable. It has super short-circuit protection function, which can make the high-voltage output work directly to the ground.


Technical parameters

Impact high voltage

035kV

High voltage partial pressure

2.5 level

Built-in capacitor

2μF

Discharge power

1225J

Impact power

2000W

Output voltage polarity

negative polarity

Impact time

about 7 seconds for automatic impact, arbitrary control time for manual impact

Over current protection

10A (more than 5 seconds) Low voltage side

Power supply

AC220V±10%, 50Hz±2Hz(60Hz)

Ambient temperature

-20+60


Back panel

High Voltage Surge Generator with Built-in 2μF Capacitor and 1225J Discharge Power 0

1. Sampling ground: The negative end of the pulse energy storage capacitor has a high voltage and must be reliably grounded. It is used for sampling when sampling waveforms under high-voltage flashover conditions of the cable fault tester. (Reliable grounding is still required for non-high-voltage flashover sampling).

2. High-voltage ground: Also known as the high-voltage tail, it must be reliably grounded to prevent high-voltage leakage and discharge. Poor contact may result in failure to boost voltage, high-voltage breakdown and damage to internal devices of the instrument, and internal leakage or discharge of the instrument causing safety accidents.

3. High-voltage output (HV OUT): Dedicated DC high-voltage output terminal.


Onsite testing case

High Voltage Surge Generator with Built-in 2μF Capacitor and 1225J Discharge Power 1

समान उत्पाद
सबसे अच्छी कीमत पाएं
सबसे अच्छी कीमत पाएं
सबसे अच्छी कीमत पाएं
सबसे अच्छी कीमत पाएं
Smart Communication Cable Fault Detector and Signal Cable Fault Locator for Accurate Fault Detection वीडियो
Smart TDR Cable Fault Locator for Low Voltage Cable Testing and Detection वीडियो
सबसे अच्छी कीमत पाएं
Smart TDR Cable Fault Locator for Signal and Communication Cable Detection वीडियो
सबसे अच्छी कीमत पाएं